Automatic Firefighting Water Monitor
chinacoal07
chinacoal07@gmail.com
chinacoalservice@gmail.com
we provide service of enterprise's customs declaration, inspection.
Automatic
Firefighting Water Monitor Introduction
Features of
Automatic Firefighting Water Monitor
Automatic
Firefighting Water Monitor Parameter
chinacoal07@gmail.com
chinacoalservice@gmail.com
we provide service of enterprise's customs declaration, inspection.
fire
monitor, portable fire monitor , fire hydrant monitor, remote
control fire monitor
Automatic
Firefighting Water Monitor Introduction
Automatic firefighting water monitor is the infrared sensor technology,
signal processing communication technology, control technology, computer
technology and mechanical technology organically unifies in together, can
automatically monitor the fire within the scope of protection. Once the fire
happens, fire extinguishing device immediately start, Intelligent scanning of
fire source in horizontal and vertical direction, after determine fire two
range, the central controller issued a directive, fire alarm signal is sent
out, at the same time start the water pump, open the valve, fire extinguishing
device for aiming put out the fire, after put out the fire, the central
controller issued a directive stop jetting water. If there is a new fire, the
fire distinguish device will repeat the process, until all the fire was put out
to return to the monitoring state. 5L/s~10L/s full automatic fire monitor water
jet form columnar water jet, for range, large scope of protection,
extinguishing ability is very strong.
Features of
Automatic Firefighting Water Monitor
Using dual band infrared and ultraviolet composite detection technology,
find the fire early, high accuracy, wide range, without blind spots;
The position of the fire source can be fixed point and the positioning of
the water spray fire extinguishing, and the efficiency of the early fire is
high;
In fire scene, through 485 bus can manual control the water jetting
direction of fire extinguish device nozzle
Using bus system image transmission technology , combined with the field
of color image signal remote manual control;
Meet the requirements of the national standard manual, automatic and
remote manual control of the three ways;
Bus communication, less material consumption, convenient construction,
maintenance is simple and convenient;
Secondary search, no reset, greatly shortens extinguishing time
Can receive any other manufacturers’ fire automatic alarm system linkage
signal;
Light weight, compact in shape, generous and beautiful.
Automatic
Firefighting Water Monitor Parameter
|
Radius of
Protection
|
30m
|
35m
|
60m
|
|
Water
Jetting Flow
|
5L/s
|
10L/s
|
30L/s
|
|
Overall
dimensions (LXWXH)
|
400mmx380mmx450mm
|
400mmx380mmx450mm
|
582mmx320mmx310mm
|
|
Weight
|
8KG
|
9KG
|
17KG
|
|
Interface
diameter
|
DN32
|
DN32
|
DN80
|
|
Installation
height
|
4-30m
|
4-30m
|
6-30m
|
|
Rated
working pressure
|
0.6Mpa
|
0.6Mpa
|
0.6Mpa
|
|
Max. Working
pressure
|
1.0Mpa
|
1.0Mpa
|
1.0Mpa
|
|
Voltage/Power
|
AC220V/Monitoring:1W,
scan:50W
|
AC220V/Monitoring:1W,
scan:50W
|
AC220V/Monitoring:1W,
scan:50W
|
|
Communication
mode
|
RS485(communication
with field area controller)
|
RS485(communication
with field area controller)
|
RS485(communication
with field area controller)
|
|
The fire
location time
|
≤30s
|
≤30s
|
≤35s
|
|
Working
environment temperature
|
-20℃~80℃
|
-20℃~80℃
|
-20℃~80℃
|
|
Horizontal
rotation range
|
0~360°(adjustable)
|
0~360°(adjustable)
|
0~360°(adjustable)
|
|
Vertical
rotation range
|
-10°~+90°
|
-10°~+90°
|
-70°~+90°
|
|
Jet water
mode
|
Reciprocating
swing after straight injection
|
Reciprocating
swing after straight injection
|
Reciprocating
swing after straight injection
|

Comments