fixed gas detector,
Radio-based fixed gas detector, hydrogen gas detector, battery operated lpg gas
detector
Device description
SL-101 is a fixed gas detector installed in
a place where potential gas hazard exists to measure oxygen, toxic gas and
combustible gas. It hows not only the concentration of gas but also iagnostic
result of the unit itself through the LCD display and can be connected to the
controller with RF commucation wirelessly.
Major Applications
Steelworks, petrochemical, refining,
shipbuilding, wastewater treatment plants and septic, mining, power, carriers,
tanks, confined space work area.
Features
01. Easy Installation/removal because no
wiring works are required
02. Economic system which doesn’t require
any wiring construction
03. Water/Dust proof structure
04. Same functions with Fixed Gas Detector
working with wiring electrical power source
05. Tracking is possible with its own
address
06. Maintenance and Replacement are simple
Specification
|
Model
|
SL-101
|
||||
|
Measuring gas
|
CO
|
H2S
|
CL2
|
O2
|
HCL
|
|
Measuring type
|
Diffusion Type
|
||||
|
Measuring method
|
Electrochemical cell
|
||||
|
Measuring range
|
0~500ppm
|
0~100ppm
|
0~20ppm
|
0~30%Vol
|
0~20ppm
|
|
Sensor life time
|
> 2year
|
> 2year
|
> 2year
|
> 18Month
|
> 2year
|
|
Response time
|
< 30sec/90%scale
|
< 30sec/90%scale
|
< 60sec/90%scale
|
< 90sec/90%scale
|
< 300sec/90%scale
|
|
Accuracy
|
±3%/Full scale
|
||||
|
Resolution
|
1ppm
|
0.1ppm
|
0.1ppm
|
0.1%
|
1ppm
|
|
Parameter Control
|
Front switch(calibration, maintenance,
alarm setting)
|
||||
|
Operation mode display
|
4-LED(Power, 2-stage alarm, 1-trouble)
|
||||
|
Measuring value display
|
LCD Display(4-digit), Built in back light
|
||||
|
Alarm display
|
Visual : 2-stage alarm, Trouble LED
|
||||
|
Alarm output signal
|
2-stage alarm, Trouble
AC250V 5A relay contact(SPDT) |
||||
|
Alarm level set
|
Programmable within dectection range
|
||||
|
Alarm signal output
|
250V 1A/3-SPST relay contact(2-stage
alarm, 1-trouble)
|
||||
|
Frequency
|
433MHz, 914MHz, 2.45Ghz
|
||||
|
Mounting type
|
Wall mount
|
||||
|
Program set mode
|
Alarm value(1,2 alarm)
4-20mA Calibration |
||||
|
Operating temperature
|
-20℃~50℃
|
||||
|
Operating humidity
|
5% to 99% RH(Non-condensing)
|
||||
|
Battery power
|
Battery : 3.6V 1.46A
|
||||
|
Battery life time
|
6~12Month
|
||||
|
Materianl
|
Aluminium, Stainless steel(STS304)
|
||||
|
LCD size
|
55(W) X 30(H) mm
|
||||
|
Dimensions
|
150(W) × 165(H) × 110(D)mm
|
||||
|
Weight
|
1.9kg
|
||||
|
Approval
|
Ex d IIC T5 IP65(KTL)
|
||||

Comments