Fixed gas detector SI-100 with display screen
chinacoal07@gmail.com
https://www.chinacoalintl.com#tanya
https://m.chinacoalintl.com/
we provide service of enterprise's customs declaration, inspection.
gas detector, fixed gas
detector, ch4 gas detector, natural gas detector
Product Introduction
Device description
SI-100 is a fixed gas detector installed in
a place where potential gas hazard exists to measure oxygen, toxic gas and
combustible gas. It shows not only the concentration of gas but also diagnostic
result of the unit itself through the LCD display and can be connected to the
controller with a standard 4-20mA analog output communication or RS-485 digital
communication.
Major Applications
Steelworks, petrochemical, refining,
shipbuilding, waste water treatment plants and septic, mining, power, agency,
changes, confined space work area
Features
01. SI-100 measures the concentration of
the flammable gas, toxic gas, oxygen and display with LCD
02. Easy magnetic bar operation
03. Big digital LCD installed with a blue
back light
04. Explosive proof structure
05. Water/dust proof structure
06. Simple gas calibration
07. RUSSIA Goat-R Certification
08. EUROPE electromagnetic waves fitness
Certification
Specification
|
Model
|
SI-100
|
|||
|
Measuring gas
|
CH4
|
O2
|
CO, H2S, SO2, NH3
|
H2
|
|
Measuring type
|
Diffusion Type
|
|||
|
Measuring method
|
Catalytic
|
Galvanic
|
Electrochemical cell
|
Electrochemical cell
|
|
Measuring range
|
0~100%LEL
|
0~30%VOL
|
CO : 0~500ppm,
H2S : 0~100ppm, SO2 : 0~20ppm, NH3 : 0~100ppm |
0~1,000ppm
|
|
Sensor life time
|
> 2 years
|
> 18Month
|
> 2 year
|
> 2 year
|
|
Measuring method
|
< 15sec/90%scale
|
< 15sec/90%scale
|
< 30sec/90%scale
|
< 30sec/90%scale
|
|
Accuracy
|
±3%/Full scale
|
|||
|
Resolution
|
1%LEL
|
0.1%VOL
|
1PPM
|
1PPM
|
|
Parameter Control
|
Front 3 magnetic switch(calibration,
maintenance, alarm setting)
|
|||
|
Operation mode display
|
Digital LCD display, LCD Back light, 4
Indicator LED
|
|||
|
Measuring value display
|
Digital LCD Display(4-digit)
|
|||
|
Alarm display
|
Visual : LCD alarm display, LCD
Back light, Indicator LED
|
|||
|
Alarm output signal
|
Relay contact(Max 30Vdc, 5A) when Alarm
occurred
|
|||
|
Alarm level set
|
Programmable within detection range
|
|||
|
Output signal
|
Analog : 4-20mA, Digital : RS-485(Option)
|
|||
|
PC inter ace
|
RS_485(Option)
|
|||
|
Cable/Distance
|
Power + Signal cable : 3-wire
1.5sq(AWG16)/2,500m max,
RS-485 data communication cable : 1 pair(UL2919 RS-485)/1,200m max |
|||
|
Conduit connection
|
NPT 3/4" (2way)
|
|||
|
Mounting type
|
Wall mount
|
|||
|
Program set mode
|
"Alarm value(1,2,3 alarm)
Alarm time(instant&delay)1~30min Alarm dead band Relay output on/off |
|||
|
Operating temperature
|
-20℃~50℃
|
|||
|
Operating humidity
|
5% to 95% RH(Non-condensing)
|
|||
|
Operating power
|
10~30Vdc 600mA
|
|||
|
Material
|
Aluminum, Stainless steel(STS304)
|
|||
|
LCD size
|
55(W) X 30(H) mm
|
|||
|
Dimensions
|
135(W) × 164(H) × 110(D)mm
|
|||
|
Weight
|
1.9kg
|
|||
|
Approval
|
Ex d IIC T5 IP65(IECEx)
|
|||